Combination of PRT-8A Heating Platform & POL1100 Polarizing Microscope
Tags: Micro Melting Point Apparatus
PLJ135A-8A is a combination of PRT-8A Heating Platform & POL1100 Polarizing Microscope.
POL1100 Series polarization microscopes are utilized polarize light to observe and research the polarize characteristic of the matter which have the double refraction .They can be used to medical inspection, such as the frame detail of the nerve fibre, the animal muscle, the plant fibre and the crystal of the tooth, bone, hair and alive cell etc. It can be observe the fine frame of the biochemistry salt crystal that the fine frame can't be observe for nature light.
PRT-8A has unique solid seamless heat structure, which conducting heat fast and giving uniform temperature. It has long service life, small size, large power, low energy consumption, rapid heating, source without oxidation. Special thermodynamic isolation design, isolating the high and low temperature parts effectively. It is safe to hold the outer body without water cooling when the stage’s temperature up to 400°C. Direct current low voltage is safe and without radiation.
This instrument is specially developed for materials science, biochemistry, metallurgy, organic chemistry, polymer and nano-material science. It is used in conjunction with optical or electron microscope to observe and record the state and changes in the process of dissolution, sublimation and crystallization. And the use of humanized design, high degree of automation, simple operation, advanced technology, excellent performance, reliable structure, will be accurate, efficient, safe, reliable assist your research, work and study.
PLJ135A-8A
Specification for PLJ135A-8A | ||
---|---|---|
Specification for Polarizing Microscope POL1100 | ||
Eyepiece | WF 10X (Φ18mm) | |
Eyepiece Tube | Trinocular, inclined 30˚ | |
Objective | Achromatic objectives 4X/0.10 | |
Achromatic objectives 10X/0.25 | ||
Achromatic objectives 40X/0.65 (Spring) | ||
Achromatic objectives 100X/1.25(Spring, oil) | ||
Magnification | 40X--1000X | |
Nosepiece | Quadruple (Backward ball bearing inner locating) | |
Polarization Analyzer | Sliding | |
Stage | Rotatable stage(Diameter: 120mm) | Double layer mechanical stage with (100mm) rotatable stage (Size:135mmX125mm Moving range:75mmX35mm) |
Focus System | Coaxial coarse/fine focus system, with tension adjustable and up stop, minimum division of fine focusing is 2.0μm | |
Abbe Condenser | NA.1.25 Rack & pinion adjustable | |
Filter | Blue | |
Frosted | ||
Polarizer | 360° rotatable stage | |
Collector | For illumination with halogen lamp With field diaphragm | |
Illumination Unit | With polarizer,6V 20W halogen lamp, adjustable brightness | |
Specification for Heating Platform PRT-8A | ||
Input Power | AC 220V ±10%,45-60Hz | |
Power | 75W | |
Tem. Range | Room~ 400°C | |
Body Tem. | Room 25°C, ≤70℃ | |
Work Mode | Constant | |
Measure Accuracy | ±0.5℃ | |
The fastest speed of Heating up | 10°C per Sec. | |
The lowest speed of Heating up | 0.1°C per Sec. | |
Speed Range Set | 0.5-36 sec/℃ | |
Immediate Constant Tem. Response Time | ≤0.01 sec | |
Size | Aluminum, 109mm | |
Central Heating Size | Chrome Plated Brass | |
Central Hole Diameter | 3mm | |
Sectional Calibration of temperature before delivery |